OZANA SR-FCRO — Composite Flow Cartridge

*The lighting effects visible in some images are graphic elements used for presentation and are not part of the physical product.

★★★★★4,000+ reviews

OZANA cartridge

Compatible with FlowComposite cartridgeAnnual OZANA replacementFlushing required

SR-FCRO — Composite Flow Cartridge

Flow
Composite replacement cartridge for OZANA Flow.
The replacement cartridge combines the treatment stages for the Flow configuration in a compact format dedicated to the system.

Installation by a qualified professional is recommended.

99.99$

Helps reduce and/or remove

Sediment

Flow prefiltration helps retain certain particles before the membrane.

Tastes and odours

Carbon media helps improve certain taste and odour characteristics.

Dissolved solids

The Flow RO membrane is designed to help reduce a large proportion of dissolved solids.

Filtration

The composite cartridge dedicated to Flow

The documented Flow configuration combines prefiltration, carbon, scale control and a reverse-osmosis membrane. The exact composition and reference delivered must match the product label.

Step 01.Prefiltration

Helps retain certain suspended particles.

Step 02.Carbon

Helps treat certain taste and odour characteristics.

Step 03.Scale-control treatment

Completes the configuration under the specified operating conditions.

Step 04.Reverse osmosis

The RO membrane is the main dissolved-solids reduction stage.

System data

Technical specifications

The published specifications reflect the information currently documented for this system.

General and performance
TypeComposite replacement cartridge
CompatibilityOZANA Flow only
Documented configurationPrefiltration, carbon, scale control and RO membrane
Nominal system capacity600 GPD
Conditions and connections
OZANA maintenanceAbout 12 months
FlushingRequired after replacement
Recommended sourcePotable municipal cold water

Maintenance

Maintenance

OZANA recommends replacement about every 12 months, or sooner depending on water quality, use and reduced flow.

Use only a reference confirmed as compatible with the purchased OZANA Flow configuration.

Before first use

Recommended use

Use with potable municipal or verified cold water. Do not use with microbiologically unsafe water or water of unknown quality without suitable treatment. Shut off the water and release pressure before replacement.

Installation and maintenance in accordance with the instructions help the system operate properly.

Compatible with OZANA FlowPotable municipal cold waterApproximately annual replacementFlush after replacement

Depending on the system

Filtration designed to improve your water quality

Actual results vary with water quality, installation, flow rate and maintenance.

OZANA SR-FCRO — Composite Flow CartridgeComposite cartridgeFlow 600 GPDAbout 12 months

Helps reduce

Sediment

Tastes and odours

Dissolved solids

OZANA selection

Ozana certified

We select our systems and components according to recognized standards for performance, material quality and safety.

Documentation availableAppropriate technology

Installation

Replace the Flow cartridge safely

Shut off the water, release pressure, confirm reference compatibility and flush before drinking.

Watch the video
01.Shut off the water

Shut off the cold water and release system pressure before handling.

02.Remove the old cartridge

Disconnect and remove it using the Flow configuration mechanism.

03.Install the new cartridge

Check the seals, insert the compatible cartridge and secure every connection.

04.Check and flush

Open the water gradually, check for leaks and flush according to the supplied instructions.

Discover OZANA

Planned maintenance for your Flow

The annual set includes the cartridge scheduled according to the OZANA interval.

View products

Use your OZANA properly

Installation designed for your space.

Read the instructions before installation and first use.

Installation and first use
  1. Shut off the cold-water supply and release pressure.
  2. Remove the old cartridge using the Flow configuration mechanism.
  3. Check the seals and install the new compatible cartridge.
  4. Open the water gradually and check every connection.
  5. Flush according to the supplied instructions before drinking.
Maintenance and replacement

OZANA recommends replacement about every 12 months, or sooner depending on water quality, use and reduced flow.

Use only a reference confirmed as compatible with the purchased OZANA Flow configuration.

Cartridge and filtration

The documented Flow configuration combines prefiltration, carbon, scale control and a reverse-osmosis membrane. The exact composition and reference delivered must match the product label.

In the box

One composite replacement cartridge for OZANA Flow.

Certifications and compliance

No performance certification is claimed without a certificate specifically identifying the cartridge and the OZANA Flow configuration sold.

Full description

The replacement cartridge combines the treatment stages for the Flow configuration in a compact format dedicated to the system.

Stay informed.

Maintenance tips, new products and useful filtration information.
A clear newsletter, sent in moderation.